Home|Products and solutions|Support|Company|Contacts|Quality


IPS products overview
Triple-Play solution
MiniMSAN mini remote MSAN
EMX-N44 mini remote IP-DSLAM
EMX-N48 mini remote IP-DSLAM
EMX-N4C mini remote IP-DSLAM
EMX - SHDSL Pair Gain
PTS - G.SHDSL Modems
SDN Remote Powering System
EMX for payphones
VFA 5.2 Access Node
FCM - HDSL Pair Gain
Network Management System
Accessories
SDN- System for remote power feeding over multiple copper pairs

Trends in Telecommunications and related problems

The demand for bandwidth in copper access network is expanding exponentially and thus putting high pressure on existing networks. For sure fibre can provide the best answer for bandwidth-hungry applications, however it is an also capital-hungry and time consuming solution. Telecom operators can not afford to wait for the »final solution«. The »solution today« is to bring the edge of the network to remote locations, closer to end customers. In this case copper pairs can deliver enough bandwidth for today's need (triple play).

Installing the edge equipment (e.g. DSLAMs) closer to end-users has one major problem: how to power the remote equipment? When providing electricity supply one always faces many problems: construction and safety problems, local authority’s permissions, building permits, private property legal problems, electricity counters installation, charging& billing. etc ...... And it is even more difficult to ensure uninterruptible power supply (UPS) which on top of everything needs regular maintenance!

Trends in Telecommunications and related problems

The solution is to use SDN Remote Powering System to provide power from existing edge points (e.g. central offices, existing street cabinets....) where uninterruptible power supply is already available. SDN system uses up to 16 copper pairs in order to provide up to 200 W on 48 VDC on remote location, using 48 VDC source in Central Office.

System consists of two units: Central-office Unit (CU) unit which connects to 48 VDC power source (UPS) in Central Office or similar place and Remote Unit (RU) unit which is installed on remote premises in small street cabinet or similar. Up to 16 parallel copper pairs are used to transport the power from CU to RU. The system is built modularly, meaning for each pair there is a dedicated module on CU and RU which may be omitted if less than 16 copper pairs are available or lesser power is needed. Range of transported power is from 15 to 170 W. Both units fit into standard 19'' rack with 1 HU height.

Technology used in SDN System

48 VDC from Central office side is transported in the most efficient way over up to 16 pairs to remote side, strictly following safety standards EN60950 and EN60950-21. Control circuits on RU constantly regulate input currents on all lines in order to adapt to load changes and provide minimum losses on the line. Output current limiter on RU protects the unit and equipment from in-rush currents. Ethernet and RS-485 ports are available for management and supervision of the system. Additional general purpose input/output pins are available for optional sensors and/or activators.

Technical characteristics



SDN-016-S (RU)  
Input  
Max number of line used(inputs) 16
Max current on the line 55mA
Typical input voltage 300 VDC
Output  
Max out power 200 W
Max efficiency 75%
Output voltage 52 V ± 4 V
Output voltage 52 V ± 4 V
Earthing  
Earthing connection 4-pole connector(+ or -, user selectable)
   
SDN-016-E (CU)  
Output  
Max. number of lines used for powering (outputs) 16(tip SDN-16)
Max current on the line 60mA
Typical output voltage 300 VDC
Input  
Input voltage range from 36VDC to 72VDC
Max. input power 400 W
Max. efficency (SDN- 16E) 75%
Earthing  
Earthing connection + pole grounded
   
SDN-016 system  
Standards  
Safety EN60950, EN60950-21
EMC EN55022 class B, ETSI EN 300386
Operating temperature range  
Min./max. ambient temperature at relative
humidity 0%- 95%, without condensation
-20°C to 50°C
Dimensions  
Height 44 mm(1HU)
Width 482 mm(19'')
Depth 167 m
Management and control  
Ethernet RJ-45
RS485 RJ-11, galvanic isolated interface,
with additional galvanic isolated
power supply for power feeding of
extern sensor units,(8-12 VDC, 2mA
(internally limited), 1W, 1500 VDC
insulation voltage.
Digital inputs(2) Max. Voltage 80V, max. Control
current 2mA (internally limited),
galvanic isolated
Digital outputs(2) 300VDC, max. current 100mA,
galvanic isolated
   
Management system(option)  
Ethernet interface Ethernet 10Mbps, HTTP, SNMP v1.
Communication interface 2(option) RJ-485, RJ-11
Information/commands available
over HTTP and SNMP
Number of powering copper pairs
available, Number of powering
copper pairs in operation,
Values of input/output currents
and Number of powering copper pairs
available, Number of powering copper
pairs in operation, Values of
input/output currents and voltages,
Temperature inside of the unit,
Status of digital input pins,
Control of digital output pins.
Optional features With additional control modules,
which communicate via RS 485 is
possible to supervise additional
parameters like: Room temperature,
Water outflow etc.

Product Data Sheet

SDN.pdf (312 KB)